12V-200AH

Maintenance Free 12V / 200AH

Description

12V200AH

Maintenance Free 12V / 200AH

The battery is constructed by plates,separators,safety valves and container. Since the electrolyte is held by a glass-mat separator and plates,the battery can use in any direction and position without leakage.                                                                       

Outer Dimensions200AHDimensions and WeightLength ( mm / inch )……………………….………522 / 20.55Width ( mm / inch ) ………………………………….240 / 9.45Height ( mm / inch ) …………………..…….….…..216 / 8.50

Total Height ( mm / inch )……………………….….242 / 9.53

Approx.Weight( Kg / lbs )………………….…..…60 / 132.24

  Performance CharacteristicsNominal Voltage ……………………..…………………… 12VNumber of cell …………………………..…..……………… 6Design Life …………………………………..….…………. 5 years

Nominal Capacity 77°F(25°C)

20 hour rate(10A,10.5V) …………………….……..……… 200Ah

10 hour rate(18.6A,10.5V) ……………….……….…………186Ah

5 hour rate (34.4A,10.5V) ……………………..………..……172Ah

1 hour rate(130A,9.6V) …………………………..….……….130Ah

Internal Resistance

Fully Charged battery 77°F(25°C) ………….…..…….……..3mΩ

Self-Discharge

3% of capacity declined per month at 20°C(average)

Operation Temperature Range

Discharge ……………………………………..…………. -20~60°C

Charge ………………………………………..………….. -10~60°C

Storage …………………………………………………… -20~60°C

Max.Discharge Current 77°F(25°C) ……………………. 1200A(5s)

Short Circuit Current …………………………………….. 3000A

Battery Construction

COMPONENT Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
RAW MATERIAL Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid

 

Charging Methods

Application Charging method Charging Voltageat 25°C Temperature compensation coefficient of charging voltage Max.charging current Charging time25°C(h) Temp(°C)
100% discharge 50% discharge
For standby power source Constant voltage &ConstantCurrentCharging(with current restriction) 13.4-13.8V -18 mV/°C 60A 24 20 0~40(32~104°F)
Forcycle service 14.5-15.0V -30 mV/°C 60A 16 10

*Temperature compensation of charging voltage is not needed.when using the batteries within 15°C to 35°C range.

 

200 AH2 copyDischarge Constant Current (Amperes at 77°F25°C)

F.V/Time 5min 10min 15min 30min 45min 1h 2h 3h 5h 8h 10h 20h
9.60V 700 560 400 231 164 120 70.0 50.5 34.4 22.5 18.8 10.2
9.90V 680 540 380 225 161 118 69.5 50.4 34.1 22.5 18.8 10.2
10.20V 640 500 360 220 160 116 69.1 50.0 34.0 22.4 18.5 10.0
10.50V 560 420 340 208 159 114 68.0 49.5 34.0 22.1 18.5 10.0
10.80V 500 360 320 180 156 110 66.0 48.0 33.6 22.1 18.1 9.81


Discharge Constant Power (Watts/cell at 77°F25°C)

F.V/Time 5min 10min 15min 30min 45min 1h 2h 3h 5h 8h 10h 20h
9.60V 7650 6126 4422 2670 1872 1506 810 586 398 263 219 120
9.90V 7326 5880 4176 2586 1848 1470 798 583 396 262 218 120
10.20V 6984 5526 3978 2466 1824 1470 792 579 394 262 218 119
10.50V 6120 4674 3762 2310 1800 1446 786 573 394 259 216 117
10.80V 5466 4200 3546 2010 1776 1434 762 555 391 259 213 115